Why ordinary ductwork does not fit
A conventional system pushes a large volume of air slowly through wide sheet-metal ducts. The main trunk can be a foot deep or more. A suburban house hides it in a basement or attic and branches off between framing. Old city buildings fight this at every step:
- Floor joists in a row house usually span from party wall to party wall, so a duct can run along a joist bay but cannot cross the house without going under the joists.
- Walls are solid masonry or plaster on lath with shallow cavities, already shared with pipes, old gas lines and wiring.
- Ceilings are often original plaster, sometimes with moldings nobody wants to lose.
- In an apartment the ceiling, the floor and most walls belong partly to someone else.
The answer is to move less air through smaller paths, or to keep the paths very short.
Four ways to get ducted cooling
| Approach | How the air travels | Fits best | Watch for |
|---|---|---|---|
| Conventional split system | Full-size ducts from an air handler in a cellar, attic or closet | Detached and semi-detached houses, gut renovations, houses that already have furnace ducts | Soffits on every floor if the house was not built for it |
| Small-duct high-velocity | Insulated flexible tubes about two inches across, fed at higher pressure, ending in small round outlets | Brownstones and pre-war houses where plaster and trim stay | Needs careful design to stay quiet; fewer installers know it well |
| Ducted mini split | A slim concealed unit in a dropped ceiling with a few short duct runs to nearby rooms | One floor or one apartment; two or three rooms off a hall | Low fan pressure, so runs must be short and straight |
| Ductless mini split | No ducts; each room has its own unit | Anywhere a soffit is not wanted | A visible unit in each room. See the ductless guide |
The hallway soffit
The most common layout in apartments and row house floors uses the hall. The hall ceiling drops by roughly a foot, a concealed unit sits above it, and short ducts pass through the hall walls into the rooms on either side, ending in grilles high on the wall. The rooms keep their full ceiling height and their plaster.
A ducted mini split above a hallway
- Concealed unit above the dropped hall ceiling, with a panel below for filter changes and service.
- Supply grille high on the room wall. Cool air falls across the room.
- Return air drawn up from the hall. Bedroom doors need a gap or a transfer grille so air can get back.
- The rooms themselves keep their original ceilings.
Three details decide whether this works. The unit needs a drain with real pitch, or a pump. It needs an access panel big enough to remove the fan and filter, not just to look at them. And closed doors must not starve the return, or the bedrooms get little air while the hall gets cold.
Where the equipment goes, by building
Brownstones and row houses
The top floor is easiest: an air handler in the roof space or a top-floor closet feeds the rooms below it through the ceiling. The parlor and garden floors can be served from the cellar through the floor. The floors in between are the problem, and they are where small-duct tubes threaded through closets, or a ducted or ductless mini split, earn their place. Many houses end up with two or three separate systems, which also gives each floor its own thermostat.
Apartments
A ducted mini split in a hall or closet soffit is the usual route, subject to the building. The hard parts are the same as for any split system: a place for the outdoor unit, a route for the refrigerant lines, and the alteration agreement. The placement and approvals guide covers them.
Detached houses in the outer boroughs
If the house has a forced-air furnace, the ducts are already there. A cooling coil goes on top of the furnace and a condensing unit goes outside. Old heating ducts are often undersized for cooling and leaky, so have them measured and sealed before trusting them.
Ratings and refrigerant
Central air conditioners and heat pumps are rated in SEER2 for seasonal cooling efficiency. In the northern states, which include New York, the federal minimum for new split air conditioners is 13.4 SEER2, and split heat pumps must reach 14.3 SEER2 and 7.5 HSPF2 nationwide. Variable-speed equipment sits well above those floors and is quieter. It also dehumidifies better, which matters in a New York August.
New equipment uses R-454B or R-32 refrigerant in place of R-410A. An existing R-410A system can still be serviced, but when an old outdoor unit fails, the indoor coil generally has to be replaced with it, because the new refrigerants are not a drop-in.
If you are putting in central cooling anyway, price a heat pump version. It is the same equipment with a reversing valve, and it gives you efficient heat for spring and fall, or for the whole winter if the building suits it. See how that plays with radiators in the steam and boiler guide.
What to ask before signing
- Was a room-by-room load calculation done, or was the size guessed from floor area?
- Where exactly will each soffit, grille and access panel be? Ask for it drawn on a plan.
- How does return air get back from every closed room?
- Where does the condensate go, and what happens if the drain blocks? A float switch that shuts the unit off is cheap insurance over a finished ceiling.
- Who files the electrical and any structural work, and what does the building need from the contractor?
- How will the filter be reached, and how often?
Once it is running, most of the savings come from how it is used. The home cost-saving guide has the short list.