The five types at a glance
| Building | Heat | Cooling as built | Who controls it |
|---|---|---|---|
| Pre-war walk-up | One-pipe steam from a cellar boiler | None | The owner; residents have a radiator valve |
| Post-war elevator building | Steam or hot water, often through wall units | Wall sleeves or PTACs; some have building chilled water | The building for the plant; the resident for the room unit |
| Brownstone or row house | Steam or hot-water boiler; sometimes a furnace | None | The owner of the house |
| New condo | Heat pumps or fan coils in each apartment | The same units | The resident, by thermostat |
| Detached outer-borough house | Furnace, or boiler with radiators or baseboard | Central air on ducts, or none | The owner of the house |
Pre-war walk-up
Four to six stories, built before the Second World War, brick walls, a fire escape on the front or back. Heat is nearly always one-pipe steam: a single boiler, risers passing up through every apartment, and a cast iron radiator in each room. One control runs the whole building, so the lower and nearer apartments tend to overheat while the far corners lag.
There is no cooling and no obvious place to add it. Electrical service to each apartment is often small, which limits how many window units can run at once without tripping a breaker. Window units are the default. A window that opens onto a fire escape is an exit and should not be blocked by one. A mini split is possible where the owner consents and there is a roof or rear wall for the outdoor unit.
Usual trouble: banging radiators, apartments too hot, vents spitting water. Nearly all of it is covered in the steam guide.
Post-war elevator building
The white and red brick apartment houses of the 1950s to 1970s were the first built with air conditioning in mind. Look under the windows. A metal grille on the outside wall means a sleeve, holding either a through-wall air conditioner or a PTAC, a packaged unit that both cools and heats. PTACs may heat with electric resistance, with a built-in heat pump, or with a coil fed by the building's steam or hot water.
Some buildings of this era instead have fan coil units fed by central chilled and hot water. In a two-pipe version the whole building is switched from heating to cooling in spring and back in fall, and residents get whichever the building is providing that week.
What you can change is usually limited to the unit in the sleeve. It must match the sleeve's size and the building's hookups, and many buildings keep an approved list. Usual trouble: drafts and water around old sleeves, noisy units, and the weeks in May and October when the building is in the wrong mode. The comparison of window, sleeve and split units has more.
Brownstone or row house
Three to five floors between party walls, with a cellar, a roof and a rear yard. The owner controls all of it, which makes this the most flexible type and the one with the most decisions. Original heat is a steam or hot-water boiler; renovated houses may have a furnace or heat pumps.
Cooling is added by the owner. The common routes are a multi-zone mini split with the outdoor unit on the roof or in the yard, a small-duct or ducted system serving one or two floors, or a mix. The difficulty is vertical: getting refrigerant lines, drains and wiring up or down four stories of masonry without wrecking plaster. In a historic district, anything visible from the street is reviewed. See placement and approvals and central air in old housing.
New condo or rental tower
Buildings from the last two decades usually give each apartment its own thermostat. Behind it is one of a few systems:
- PTACs or packaged heat pumps in wall sleeves, like the post-war buildings but newer.
- Water-source heat pumps in a closet or ceiling, connected to a building water loop.
- Fan coils with heating and cooling available all year.
- Variable refrigerant flow systems, which are large multi-zone heat pumps shared across apartments or floors.
The owner or tenant is usually responsible for the unit inside the apartment: filters, the condensate drain, and repairs under the building's rules. The most common trouble is a neglected filter or a blocked drain that overflows into the apartment below. Find the filter, learn its size and change it on a schedule. Recent buildings are increasingly all-electric, with no gas for heat.
Detached or semi-detached house
Common in eastern Queens, southern Brooklyn, the north Bronx and most of Staten Island. These houses work like suburban ones. Heat is a gas or oil furnace with ducts, or a boiler feeding radiators or baseboard. If there are ducts, central air uses them; if not, the choices are the same ductless and small-duct systems used in row houses, with the advantage of side yards and four outside walls.
Usual trouble: ducts that were sized for heat and are too small or too leaky for cooling, oversized old furnaces, and condensers placed too close to a neighbor's window. Attached brick houses in Queens and Brooklyn sit between this type and the row house, with party walls on the sides and a driveway or yard at the rear.
What stays the same everywhere
- Shared walls, roofs and risers belong to the building, not the apartment.
- Electrical, gas and structural work is filed by licensed professionals.
- Heat thrown outdoors, noise and dripping water are a neighbor's business as soon as they cross the property line.
Next, see cooling options from least to most invasive or who controls the heat. Back to the five-borough guides.