What most houses have
Nassau and Suffolk filled with capes, ranches, split-levels and colonials in the decades after the Second World War. The usual heating plant is a boiler in the basement or utility room, fired by oil or natural gas, sending hot water through finned baseboard along the outside walls. Oil remains common because many streets have no gas main. Older houses nearer the city may have cast iron radiators or steam, which the steam and boiler guide covers.
In many houses the boiler also makes the domestic hot water, either through a coil inside the boiler or through a separate indirect tank. That matters when you think about replacing it: take the boiler away and the hot water goes with it.
Boiler and baseboard care
- Have an oil burner cleaned and tuned every year: nozzle, filter, electrodes, combustion test, and a look at the chimney. Gas boilers need less, but still a yearly check.
- Keep baseboard covers on, fins vacuumed and the damper flap open. Carpet and furniture pushed against baseboard cut its output sharply.
- Zone valves and circulators fail more often than boilers. One cold zone with a warm boiler points at one of them, or at air in that loop.
- Know your oil tank. An old tank, buried or above ground, is worth having inspected before it leaks. Tank rules are set locally, so check with your town or county.
- Keep carbon monoxide alarms on every level.
Adding cooling to a house with no ducts
| House type | What usually works | Catch |
|---|---|---|
| Ranch | An air handler in the attic with ducts to ceiling registers in every room | Everything depends on how well the attic ducts are sealed and insulated |
| Colonial | Attic system for the upstairs; a second system, ductless units, or ducts dropped through closets for downstairs | One attic system rarely cools the first floor well |
| Cape | Ductless units, or a small ducted unit behind the knee walls | Sloped ceilings leave almost no attic; upstairs rooms run hot |
| Split-level | Ductless or a mix of small ducted zones by level | Each level behaves like a separate house |
Attic air handlers
Putting the equipment in the attic is the standard Long Island solution because it is the only unclaimed space. It works, with conditions. A summer attic is the hottest place in the house, so every leak and every thin spot of duct insulation costs more there than anywhere. Ask for sealed, well-insulated ducts, a return large enough to be quiet, a secondary drain pan under the unit with a float switch that shuts it off if the drain blocks, and a safe, lit path to reach the filter. Better still, where the roof allows, is to insulate at the roofline so the equipment sits inside the conditioned part of the house.
Ductless
A ductless mini split avoids the attic entirely, which suits capes, additions, finished basements and the bonus room over the garage. Detached houses make placement simple: a pad beside the house, a short line set, and four outside walls to choose from. Sizing room by room matters just as much as in an apartment; the sizing table applies.
Where heat pumps fit
Any central air conditioner or ductless system can be bought as a heat pump, and on Long Island that is usually worth doing, because it gives a second heating system that runs on electricity instead of oil.
- Ductless heat pumps heat from low on the wall or from a floor console and work well as primary heat in the rooms they serve, with the baseboard as backup for the coldest nights.
- Attic ducted heat pumps heat through ceiling registers. Warm air delivered at the ceiling tends to stay there, so this arrangement is better as shoulder-season heat than as the only heat, unless the house is tight and well insulated.
- Air-to-water heat pumps can feed a hydronic system, but ordinary baseboard was sized for much hotter water than they like to make. They suit radiant floors and oversized radiators more than standard fin-tube.
The common, low-risk pattern is hybrid: heat pumps carry the house for most of the season and the boiler stays for deep cold and hot water. Going fully electric means sizing the heat pumps to the winter load, checking the electrical service, and replacing the water heater. Air sealing and attic insulation come first, since they shrink the equipment you need. Utility and state incentive programs change often, so check what is currently offered and what conditions apply.
Oil, gas or electric when the boiler dies
If the boiler fails in winter, a like-for-like replacement is the fast answer. If you have time, compare three things: whether gas is available in the street, what a heat pump could cover with the old boiler kept as backup, and how you will make hot water. A new boiler should be sized to a heat-loss calculation, not to the old one's label, because most were oversized.
Shoreline houses
Near the bays and the ocean, two extra things matter. Salt air corrodes outdoor coils, so look for coated coils and corrosion-resistant cabinets, and rinse the unit gently with fresh water a few times a season. In flood zones, outdoor units, boilers, tanks and electrical panels should sit above the expected flood level, on a raised platform or an upper floor. Local building departments set the required elevation.
Related guides
Houses with furnaces and ducts are covered in the furnace guide and the central air guide. For running costs, see the cost-saving ideas. City apartments and row houses are sorted by building type in the five-borough guides.